Half the time a Thermal Imaging Inspection Bonnyville request has nothing to do with a bungalow. It comes from somebody paying to heat a service bay off the highway, where the unit heaters run flat out all through February and the parts counter at the front is still too cold to stand at. The other half is the house. Either way the instrument is the same and so is the question it answers. An Infrared Home Inspection Bonnyville puts a number-free picture on the wall of where the building is giving warmth away, which beats guessing and beats a sales pitch.
What an infrared camera proves, and what it has no opinion about
Think of the device as a thermometer that reads a whole surface at once instead of one spot. It tells us how warm or cool the face of something is - gyproc, steel liner, a concrete curb - and that is the entire extent of its knowledge. It has no opinion about what lies behind that face. It will not report an R-value, since R-value describes the stuff in the cavity and the camera cannot identify the stuff. It will not peer through a wall assembly either; anybody promising x-ray vision is selling something else. We work the other direction: heat leaving a building disturbs the temperature of its interior surfaces, and that disturbance is legible if you catch it in the right conditions.
Thermal imaging in a Bonnyville shop, not only a house
Steel buildings on the service yards tell their story quickly. Overhead door jambs and the header above them show up first, then the junction where the wall sheeting meets the slab, then every bolt and purlin line as a cool grid that is simply the metal doing what metal does. A mezzanine office built inside an unlined shell is its own case - the floor of it sits over cold air, and from below we can see the warm footprint of the room above, which is exactly the heat somebody is paying for twice. In houses the pattern is different again: about 62% of the stock here predates 1991, which puts a great many lap-sided bungalows and early split-levels in front of us, and those tend to leak at the top of the wall where it meets the attic.
Hard frost is a piece of equipment we borrow for free
None of this works in shoulder season. The lens separates warm from cool, so when the two sides of a wall are nearly the same temperature there is nothing to separate and the picture turns to porridge. A deep cold morning is doing half our work: the bigger the offset between inside and outside, the more plainly heat routes itself through the weak spots. We avoid direct sun on the elevation being scanned for the same reason - a wall that has been sitting in low winter sun holds that warmth and buries the signal underneath it.
Draught, void and dampness are three different pictures
A draught arrives as a tail. It streams away from its entry point, widest at the opening and thinning as it goes, and it answers to pressure - close a door, switch on an exhaust fan, and the tail lengthens or dies.
A void is architecture. It holds a shape with straight sides, repeats on the same spacing as the framing or the purlins, and is completely indifferent to what the fans are doing. Where one bay reads noticeably cooler than the bays either side of it, something in there has settled, been cut away for wiring, or was never filled.
Dampness behaves unlike either. Water pulls heat out as it evaporates, so a wet area lags - it stays cool while dry surfaces around it respond to a rising thermostat, and it is still lagging twenty minutes later. Watching how a patch changes, rather than how it looks in one frame, is what tells us which of the three we are looking at.
What leaves with you at the end
A folder of annotated frames keyed to a floor plan or a bay number, a short written account of each one, and a recommended scope built from that account. Some of those findings call for closed cell at about R-6 per inch, which is its own air barrier and vapour retarder and the usual answer against steel or below grade. Others want the depth and sound absorption of open cell at about R-3.6 per inch. The scan is the diagnosis, not the prescription.
Thermal Imaging Inspection Bonnyville: Common Questions
Will the scan tell me whether my shop walls have anything in them. It will tell you where they behave as though they do not, bay by bay. That is a map of where to open up, not a material report.
Can you scan a cabin at the lake in the summer. We would rather not. Summer collapses the difference the camera depends on, and the result is a pretty image that proves nothing.
We heat a shop and an office in the same building. Can one visit cover both. Yes, and it usually should - on a Bonnyville service property the boundary between a heated office and an unheated bay is often the biggest finding on the site.
Related: commercial spray foam insulation, shop spray foam insulation, metal building spray foam insulation and spray foam insulation. Across the province: Spray Foam Insulation Alberta. We will put a Free Spray Foam Quote together off the findings; the rest of our coverage is on service areas.