About 81% of homes in Fort Macleod were built before 1991, and the town also holds a stock of solid masonry buildings from considerably further back than that - brick and sandstone walls laid several courses thick, with no cavity anywhere in them. A Thermal Imaging Inspection Fort Macleod on a wall like that follows different rules from a scan of a stud wall, and anyone reading the images the usual way will misread them.
Solid masonry gives up its heat evenly, which hides the detail
A framed wall is a grid: warm studs, cooler bays, and anything wrong with it shows up as a break in that grid. Several wythes of brick have no grid. Heat moves through the whole thickness at a similar rate, so the interior face reads broadly uniform and the obvious contrast a camera is good at simply is not there. What does print is the exception - a joist pocket where the floor framing sits into the brickwork, a chimney breast, a window reveal, the band at the top where the wall meets the roof structure, and any place where water has got into the masonry and changed how it conducts.
Mass delays the picture, so when you scan matters
A thick wall is a flywheel. It takes days of weather to arrive at the inside face, which means a single cold night tells you very little about one of these buildings. The reading is worth taking at the end of a sustained cold run, not at the start of one, and emphatically not on the second day of a warm wind when the wall is still holding the previous week. Sun is the other trap: a south elevation of dark brick will store an afternoon's worth of heat and hand it back for hours. On this building type, timing is more than half of the result.
What an infrared survey of an old brick building actually resolves
It reads the face of the masonry and nothing deeper. There is no seeing through nine inches of brick and no number for the wall at the end - R-value describes resistance in an assembly, and a temperature reading does not convert into one. The honest output is a map of where this particular wall departs from its own average, which on heritage construction is most of what you need, because the losses are concentrated at the junctions rather than spread across the field.
Air, void and water on one old wall
Air arrives through the joints: around a window frame set into masonry, at a pocket where a beam enters, down a disused flue. It fans and it moves. A void is rarer here, but where a previous owner has furred and lined the inside face, the lining has its own cavity and that cavity can be empty - straight-edged cold patches on the lining, set out at the spacing of the strapping. Water is the one to respect in old brickwork: soft-edged, cooler, often rising from the base of the wall or spreading below a failed sill, and following neither strapping nor framing. Evaporation is doing the cooling, and in masonry it is also doing damage, so that finding is checked with a meter before any decision follows it.
What we hand over after a Fort Macleod scan
Images tied to locations, a ranked list of the junctions that are losing the most, and a clear statement of where a lining can be sprayed and where the wall needs to stay able to dry. That distinction matters on old masonry. Where an interior face is the right place to work, closed cell at about R-6 per inch is its own air barrier and vapour retarder, which is why it suits a surface with no cavity to vent - the detail gets set out on wall spray foam insulation, with basement spray foam insulation and crawl space spray foam insulation for what sits below. An Infrared Home Inspection Fort Macleod on a frame house in town is a far quicker visit than a survey of a masonry block.
Our own hands on both jobs
We survey the building and we spray it. The judgement calls about an old wall are made by the people who then have to live with them.
Thermal Imaging Inspection Fort Macleod: Common Questions
Does thermal imaging work on a solid brick building? It works, but it reads differently. On the masonry buildings in Fort Macleod the useful information is at the junctions - pockets, reveals, flues, the wall head - rather than across the open wall.
When should it be booked? After several cold days in a row, in the evening, with no sun having been on the elevation. One cold night behind a warm week is not enough to shift a wall that thick.
Can you tell me what the wall is rated at? No. The survey locates loss, it does not grade construction. Anyone converting a thermal image into an R-value is inventing the number.
The work itself is spray foam insulation. The province is covered at Spray Foam Insulation Alberta and our range at service areas.