An applicator in coveralls and a respirator spraying closed-cell foam between the steel ribs of a fabricated shop panel

Thermal Imaging Inspection Fort Saskatchewan

39%OF FORT SASKATCHEWAN HOMES PRE-1991
36APPLICATIONS COVERED IN FORT SASKATCHEWAN
R-6PER INCH, CLOSED-CELL
Our own installers Calgary · Edmonton · Red Deer Open 24/7 No price without a site visit
Free quote

Thermal Imaging Inspection Fort Saskatchewan: Tell Us The Building

Foam is priced on depth, area, access and prep, so the number comes after someone has seen the space. Send the details and we will come back with a real one.

Get Your Free Spray Foam Quote

Get your spray foam quote

Prefer to talk? Call (403) 703-9512

An applicator in coveralls and a respirator spraying closed-cell foam between the steel ribs of a fabricated shop panel
Supplied by Dustin 2026-08-28

Thermal Imaging Inspection Fort Saskatchewan gets asked for by maintenance people more often than by homeowners, and the buildings explain why. Sitting in the middle of the Industrial Heartland, this is a town of fabrication shops, contractor warehouses, parts stores, lunchroom and control-room buildings and modular site offices, nearly all of it clad in profiled steel and nearly all of it owned by somebody who has to justify a spend against a budget. A scan is how that case gets made with something better than an opinion from whoever was coldest last winter. About 39% of homes in Fort Saskatchewan were built before 1991, so the residential side of this work tends to be newer stock with a specific, findable fault.

A thermal imaging survey is not a test report

What comes off the camera is a map of surface temperature at a moment in time. It is evidence and it is not a performance test. There is no R-value in it, there is no leakage rate in it, and it does not look through the wall liner — it looks at the liner. Treated as a diagnostic it is extremely good. Presented as proof of a number, it is being oversold, and on an industrial building where a decision costs real money that distinction matters more than anywhere else.

Girt lines, and the finding hiding between them

Steel buildings print their own skeleton. Girts, purlins and the fasteners through them conduct, so a scan of a metal wall shows a regular ladder of cool lines and that is simply the building being itself. The finding is whatever interrupts the ladder: a bay where the pattern disappears into one broad cold field, a panel lap that fans cold air inward, a cold stripe at the base angle where the wall meets the slab, the ring around a conduit or a pipe sleeve. Knowing the module is what makes a scan of a metal building worth doing, because without it every girt looks like a defect.

The scan window in Fort Saskatchewan is narrow

Industrial buildings are often run warm and run hard, which helps, but the camera still needs cold outside to see anything at all. Mild air means no image worth reading. We also stay off sun-loaded elevations and off a wall that has had a radiant heater pointed at it, and in a shop we want the overhead doors to have been closed long enough that the slab and the steel have settled. On a plant turnaround schedule that window gets booked ahead rather than squeezed in.

Infrared is good at air, and only suggestive about water

Air movement draws itself: a plume out of a joint, spreading and thinning in the direction it is travelling, unmistakable once you have seen a few. Missing insulation draws itself differently: a bounded cold field with edges that obey the framing. Moisture does not draw itself at all — it shows as a soft cool area because evaporation removes heat from the surface, and it can be a wet wall, a wet slab or nothing at all. We confirm with a meter before anyone writes a work order against it. An Infrared Home Inspection Fort Saskatchewan follows the same rules on a smaller canvas: the rim joist, the garage ceiling, the attic hatch, the cold band above a window header.

What goes in the file

Images referenced to the building grid or to the room, each tagged as air, absence or unconfirmed moisture, and a ranked list a maintenance planner can actually work from. Then the scope: closed cell at about R-6 per inch where the surface has to be the air barrier and the vapour retarder as well as the insulation, which is most of what we do on a steel wall, and open cell at about R-3.6 per inch where the cavity is deep and dry and noise is part of the complaint.

Thermal Imaging Inspection Fort Saskatchewan: Common Questions

We need a number to put in a capital request. Can a scan give us one? Not a thermal number. It gives you a located, photographed list of defects, which is usually a stronger request than a number without a cause attached.

Our shop has cold lines every few feet. Is the insulation missing? Probably not. That is the girt pattern, and it is normal on a steel building. The finding is where the pattern breaks.

Can you do the shop and the house on the same trip? Often, yes. A Fort Saskatchewan shop scan and a house scan need the same conditions, so if the cold holds we can do both in one cold stretch.

Where the findings usually lead: metal building spray foam insulation, warehouse spray foam insulation or a commercial building insulation retrofit. See also spray foam insulation, spray foam insulation across Alberta and our service areas.

What we spray in Fort Saskatchewan

Spray Foam Applications We Cover in Fort Saskatchewan

Spray Foam Insulation Companies Fort Saskatchewan: Where We Work

We cover Fort Saskatchewan and the surrounding area. For the full service map and the rest of Alberta, start at our service areas.

Ready for a real, honest quote?

Free Spray Foam Quote