There is one fact about a Thermal Imaging Inspection Grande Cache that makes it unusually good value: this is a town that went up in a hurry, mostly in one era, to a small number of plans. About 75% of homes in Grande Cache were built before 1991, and a great many of them were put in as resource-town housing — detached units, duplexes and short rows built by the same hands in the same few years. Scan one of them properly and you have learned something about the whole street, because the detail that failed in this unit is the detail that was repeated next door.
That changes the point of the exercise. Elsewhere a scan diagnoses a house. Here it often diagnoses a type, and an owner with more than one unit can plan work in a sensible order instead of waiting for each tenant to complain in turn.
One set of construction details, repeated down a street
What we find in that stock is consistent. Insulation that has slumped in the upper third of a wall, leaving a cold band under the top plate. Party walls between attached units that were framed for fire and sound but not sealed at the attic, so air travels sideways out of one unit and up out of the next. Service penetrations through an exterior wall — the dryer vent, the old phone entry, the hose bib — left open behind the cladding. None of those are visible to a tenant. All of them are plain on the screen within a minute of the camera coming up to temperature.
Why an infrared scan needs cold, and why that is no obstacle here
The method depends entirely on heat pushing from inside to outside. Take the temperature difference away and the image goes blank. In a lot of Alberta that means hunting for a workable week; up at this elevation the cold arrives early, stays, and gives us a scanning window that runs for months rather than days. We still want the building held at a steady temperature beforehand and we still keep out of direct sun on an exterior pass, because sun on the siding will hide what is behind it.
What the camera has no opinion about
It has no opinion about what is inside a wall. It reads the temperature of the surface in front of the lens and converts that into a picture, and it stops there. R-value is not something it can produce, now or ever, because R-value belongs to the material in the cavity and the camera is outside the cavity. It also does not see through drywall, panelling or a steel skin. The reason it is worth doing anyway is that a fault inside an assembly almost always prints itself on the surface, and the camera finds that print faster and more completely than a person with a hand and a hunch.
Air, a void and water read apart on a shared wall
In attached housing the three signatures are especially worth separating. Air in motion looks blown: tapered streaks spreading from a gap, visibly altering when a door between units or to the outside is opened. A void looks cut out: a flat cold rectangle or a long band with edges that follow framing exactly, and it does not change shape no matter what we do. Water looks spilled: a vague cool area with soft irregular margins that crosses studs and plates, cold through evaporation, immune to any pressure change. In a row of similar units, knowing which of the three you are dealing with decides whether the fix is sealing, filling or finding a leak first.
Thermal imaging inspection in Grande Cache: what the report contains
An Infrared Home Inspection Grande Cache report is built to be acted on, not filed. Each finding is a marked thermal image with a matching ordinary photograph, tagged by unit and room, and sorted by the size of the loss rather than the order we walked. For an owner with several units we note which findings look like a repeated construction detail, because those are the ones worth budgeting as one job. The foam specification follows: closed cell at about R-6 per inch where the assembly needs its air barrier and vapour retarder in the same application, open cell at about R-3.6 per inch where filling a cavity and quieting a shared wall is the goal.
Thermal Imaging Inspection Grande Cache: Common Questions
I own three units on the same block. Do you need to scan all of them. Not necessarily all. We scan enough to establish whether the fault is one building or the plan, and that answer usually shapes the rest of the work.
Does it have to be bitterly cold. It has to be properly cold, which in Grande Cache is most of the winter. The colder it is outside, the clearer the image.
Can the tenants stay in. Yes. We need access to the rooms and the walls, not an empty unit, and the heating left at its normal setting.
Where this leads: wall spray foam insulation, attic spray foam insulation and basement spray foam insulation. Also spray foam insulation, Spray Foam Insulation Alberta and our service areas.