Supplied by Dustin 2026-08-28

A city with a provincial boundary running up its main street collects an unusual mixture of buildings, and that mixture is the reason a Thermal Imaging Inspection Lloydminster is worth doing before anything is specified. Heavy oil built the industrial side of this place - service yards, fabrication shops, truck bays, tank farms - and around them sit office blocks, walk-up apartment buildings and houses from every decade the town has had. An Infrared Home Inspection Lloydminster deals with the residential half. The physics does not change from one side of the street to the other, and neither does the winter.

A building does not care which province it is standing in

Whichever registry a property sits in, the weather arriving off the open country is identical, and so are the places heat gets out. What does differ is building type, and that is what we sort out with a lens. In a fabrication shop the big findings are the overhead doors, the junction where the wall sheeting lands on the slab, and any heated office built as a box inside a cold shell. In a walk-up, it is the floor over an unheated parking area, the corridor ends and the stacked plumbing chases. In a house it is the ceiling perimeter and the band at the top of the foundation. We do not have a published housing-age figure for this city to lean on, which suits us - we would rather read the actual buildings than a statistic about them.

What the thermal imaging camera actually captures

One quantity: the temperature of the surface it is pointed at. Everything else is interpretation. Two consequences get stated at the door. The image cannot give you an R-value, because R-value belongs to the insulating material inside the assembly and this instrument has no access to it - it sees a painted face, not a cavity. And it does not look through construction. Heat on its way out alters the temperature of interior finishes, the camera maps that alteration, and an experienced eye works backwards from the map to the cause. A scan is evidence, not an excavation.

Infrared wants a cold spell, not a mild one

The method lives on separation. When the air indoors and the air outdoors are close together, surfaces equalise, the image goes uniform and it proves nothing. A genuine cold snap pushes heat hard at the weak details and makes them stand out, which is why we schedule this work in the depths of the heating season and decline to pretend a shoulder-season scan means anything. Direct sun gets avoided for the same reason: a sunlit wall holds warmth that masks whatever was underneath it.

Leakage, voids and damp read three different ways

Leakage has a source and a direction. It arrives as a trail off an opening, fades as it fans out, and alters when the pressure in the building shifts - a shop with make-up air and exhaust running is changing the pressure all day, and a finding that changes with it is air.

A void is dimensional and inert. It shows as a band or block with definite edges, generally lining up with the framing or the panel layout, and it does not care about fans or doors at all.

Damp is detected by how slowly it behaves. Drying removes heat, so a wet area sits cooler than its surroundings and lags behind them while a space warms up, still lagging well after the dry surfaces have caught up. Under a flat roof or against a foundation, that lag is the useful clue.

What you receive

A written record with the images in it, each one located and interpreted, and a recommended scope tied line by line to those images. Against steel, against concrete, at a floor header or below grade, closed cell at roughly R-6 per inch is generally the answer because it serves as an air barrier and vapour retarder in the same application. Where there is a deep framed cavity, or a demising wall between residential units that ought to be quieter, open cell at roughly R-3.6 per inch adds depth and absorbs sound well. Nothing in the scope should be a mystery to you.

Thermal Imaging Inspection Lloydminster: Common Questions

We own an apartment block here. Where does a scan pay off. Usually at the floor over unheated space and at the top-floor ceiling. Those two findings in a Lloydminster walk-up tend to outweigh everything else on the building.

Can you scan a yard building that is only heated when crews are in it. Yes, provided it has been heated long enough before we arrive for the surfaces to respond. A cold building scanned cold shows nothing.

Is the industrial work the same service as a house scan. Same instrument and same reasoning, bigger building and a longer list to put in order of priority.

Related: commercial spray foam insulation, multi family spray foam insulation, commercial building insulation retrofit, spray foam insulation oilfield tanks and spray foam insulation. Province-wide: Spray Foam Insulation Alberta. A Free Spray Foam Quote follows the written record; see service areas.

What we spray in Lloydminster

Spray Foam Applications We Cover in Lloydminster

Spray Foam Insulation Companies Lloydminster: Where We Work

We cover Lloydminster and the surrounding area. For the full service map and the rest of Alberta, start at our service areas.

Ready for a real, honest quote?

Free Spray Foam Quote