Thermal Imaging Inspection Rocky Mountain House is usually arranged around a working yard rather than around a house, and the thing that dictates how we do it is the overhead door. A service shop out here has trucks and equipment going in and out from before daylight, and every cycle of that door dumps the heat and lets a slab of cold air sit inside the opening. The building spends the whole day recovering and never arrives anywhere steady. Point a camera into that and the cold standing at the doorway swamps the image, so the real findings on the far wall never appear at all.
A shop whose doors never stay shut
This is a scheduling problem with a straightforward answer, which is that we scan before the yard wakes up. The heat needs to have been running at its normal setting through the night so the steel and the slab have caught up, the doors need to have been closed long enough for the cold front inside them to dissipate, and then the image is honest. A scan taken mid-morning on a busy day is a photograph of the doors being used, which nobody is paying to find out.
The overhead door is a wall, and it reads like one
An overhead door is a large part of the envelope and it is generally the worst-performing part. On an image it shows its own pattern: the panel seams read as warm lines where the metal wraps around, the perimeter seals read as a bright outline wherever they have shrunk or been knocked out of alignment, and the gap under the bottom rubber reads as a bar of cold across the slab. Separating a door that needs adjusting from a wall that needs insulating is one of the more useful things a survey settles, because they are not the same cheque.
What an infrared survey measures, stated plainly
Surface temperature. It is a thermometer that draws pictures, and the pictures are extremely informative when they are read properly. What it does not do is report thermal resistance — there is no reading on any camera that gives you an R-value — and it does not look through steel or board. It reads the inside face, and we infer what is behind it. An Infrared Home Inspection Rocky Mountain House works on exactly the same principle in a much smaller building.
Rocky Mountain House homes and where the heat goes upstairs
About 57% of homes in Rocky Mountain House were built before 1991, and the pattern in that stock is vertical. Warm air inside a house wants to leave at the top, so the attic hatch, the top plate of an interior wall, the open bay beside a stairwell and the chase around a plumbing stack are the routes that show up over and over on an image. People expect their walls to be the problem and the ceiling plane almost always outranks them.
Thermal imaging tells shapes apart, not materials
There are three shapes and each means a different job. Moving air draws a plume: out of a joint, spreading, fading. Missing material draws a block: cold up to an edge, and the edge follows the framing that was supposed to hold the material. Water draws nothing at all, just a soft cool area with no boundary, because evaporation takes heat off whatever surface it is leaving. We treat that third one as something to confirm with a meter rather than something to report.
What we leave you with
A set of photographs organised by bay and by room, each labelled as air, absence or unverified moisture, and ordered so the biggest loss is at the top of the list. Only after that does a scope get written, and the material follows the surface: closed cell at about R-6 per inch where the surface has to be its own air barrier and vapour retarder, which is most of a steel shop, and open cell at about R-3.6 per inch in deep dry cavities where sound matters.
Thermal Imaging Inspection Rocky Mountain House: Common Questions
Can you come during the day while we are working? We can, but the image will be worth much less. Early, before the doors start cycling, is the only time a Rocky Mountain House shop scan gives a clean picture.
Is it the doors or the walls costing me money? That is one of the more common reasons people book a survey, and it is a question an image answers quickly, because a failing door seal and an empty wall bay look nothing like each other.
Does the shop have to be heated for this? Yes, and heated the way it normally is, for a good stretch beforehand. A building sitting cold has no temperature difference across its walls, and without that there is nothing for a camera to show.
What tends to follow: shop spray foam insulation, metal building spray foam insulation or attic spray foam insulation. See also spray foam insulation, spray foam insulation across Alberta and our service areas.