The complaint behind most of our Thermal Imaging Inspection Stony Plain work is a floor. Somebody has a room over the garage that is cold underfoot from November to March, the vent in it blows warm air, the thermostat downstairs says everything is fine, and three people have told them it is the furnace. It is not the furnace. It is the floor of that room, and a camera shows why in about ninety seconds.
This is a commuter town with young housing. About 35% of homes in Stony Plain were built before 1991, so the majority of the stock went up afterwards — two-storey family houses with attached garages, bonus rooms above them, cantilevered bays and finished basements. That is a particular menu of faults, and almost none of them involve a wall that lacks insulation.
A bonus room over a cold garage
The floor of a bonus room sits over an unheated space, which makes it an exterior surface even though nothing about it looks like one from inside. Three things go wrong there. The insulation is installed between the joists but nothing stops air moving in the space above or below it, so cold garage air circulates around the material instead of being held out by it. The band at the perimeter, where the floor meets the outside wall, gets missed because it is awkward. And the kneewalls either side of the room, which back onto open attic space, are often left with nothing sealing their inside face. On the screen the floor of that room is a cold field with cold edges, and the kneewalls light up beside it.
A setback thermostat makes the scan harder than it needs to be
Commuter households run deep setbacks — down while everyone is at work, up in the evening. That matters because surfaces take time to catch up with the air, and a house that was at its night setting four hours ago is still reporting the night setting at the wall. For a reliable picture we want the house held at one normal temperature for a good stretch beforehand, which usually means a weekend morning or an evening after the heat has had hours to settle. And it has to be properly cold out, because the entire method rests on heat pushing outward hard enough to leave a trace.
What an infrared camera can prove, and what it cannot
It can prove that one surface is colder than another, to a fraction of a degree, over a whole wall or ceiling at once. It cannot tell you the insulating value of what is behind that surface. There is no R-value in a thermal image, because the camera measures the face of the finish and R-value describes the material inside the assembly. It does not see through the drywall. Everything useful it produces is a pointer: here, this area, this is where the heat is going, now go and confirm what is causing it.
Three signatures: moving air, a gap, and damp
Moving air is streaky. It fans out from wherever it is entering or leaving, and the shape changes the moment we depressurise the house with a fan or open an exterior door. A gap in insulation is geometric and still — a cold rectangle between two studs, a stripe along the joists, edges hard enough to trace. Damp is the woolly one: a cool patch with no straight edge, crossing framing without regard for it, cold because water is evaporating off the surface, and perfectly unmoved by any pressure change. On a bonus-room floor we usually see the first two together, and knowing the proportion between them decides whether the job is sealing, filling, or both.
Thermal imaging inspection in Stony Plain: what the report looks like
An Infrared Home Inspection Stony Plain report is organised room by room, each finding a marked image next to a plain photograph of the same corner, with the losses ranked by size instead of by the order of the walk. From there we specify foam against what was found. Closed cell at roughly R-6 per inch comes with its own air barrier and vapour retarder, which is why it suits the underside of a bonus-room floor and a garage ceiling. Open cell at roughly R-3.6 per inch is the choice where a framed cavity needs filling and sound deadening matters.
Thermal Imaging Inspection Stony Plain: Common Questions
The room over the garage has a vent and still feels cold. Is more heat the answer. Rarely. If the floor and kneewalls are losing heat faster than the register can supply it, adding air into the room is treating the symptom.
Can you scan while we are at work. It is better if you are not setting the thermostat back that day. The house needs to have been at a steady temperature for hours before we arrive.
Our house is nearly new. Would there be anything to find. On the newer houses in Stony Plain the findings are concentrated at garage ceilings, cantilevers and kneewalls rather than spread across the walls, and they are easy to miss without a camera.
Typical next steps: bonus room spray foam insulation, garage spray foam insulation and ceiling spray foam insulation. Also spray foam insulation, Spray Foam Insulation Alberta and our service areas.