An applicator in coveralls and a respirator spraying closed-cell foam between the steel ribs of a fabricated shop panel

Thermal Imaging Inspection Whitecourt

49%OF WHITECOURT HOMES PRE-1991
36APPLICATIONS COVERED IN WHITECOURT
R-6PER INCH, CLOSED-CELL
Our own installers Calgary · Edmonton · Red Deer Open 24/7 No price without a site visit
Free quote

Thermal Imaging Inspection Whitecourt: Tell Us The Building

Foam is priced on depth, area, access and prep, so the number comes after someone has seen the space. Send the details and we will come back with a real one.

Get Your Free Spray Foam Quote

Get your spray foam quote

Prefer to talk? Call (403) 703-9512

An applicator in coveralls and a respirator spraying closed-cell foam between the steel ribs of a fabricated shop panel
Supplied by Dustin 2026-08-28

Forestry and oilfield work means buildings with doors that never stay shut. A service bay where trucks come and go all shift, a shop beside the log yard, a warehouse where a loader is in and out twenty times before lunch - every one of those openings dumps the heated air and starts the building over again. A Thermal Imaging Inspection Whitecourt on that kind of building has to account for the cycling, because a survey taken five minutes after a door closed is a survey of the door, not of the envelope. On the residential side, where about 49% of homes predate 1991, it is a more conventional exercise.

A door cycle resets the whole building

When a large door rolls up in January the warm air leaves in seconds, and what is left behind is a slab and a set of wall surfaces that are now the warmest things in the room. They give their heat back to the incoming cold air over the following half hour or so, and during that half hour the inside faces are all drifting at different rates. A camera pointed at that is measuring recovery, not performance. The nearest thing to a rule we work to: let the building close up and come back to its working temperature before anything gets recorded, and note anywhere the slab edge and the door apron are drawing cold in from outside, because that part never recovers.

When to point the infrared camera at a working shop

Early morning before the first door cycle, or after the crews have gone and the building has been shut for a couple of hours. Those are the two windows. The heaters should have run as normal, nothing should be parked against a wall that needs reading, and the surfaces being compared should have had time to settle. Taken at the right moment the picture is clean; taken at the wrong moment it is a record of what happened in the last ten minutes and nothing about the building.

Cold months only, and that is not a scheduling preference

The whole method rests on a difference between the inside surface and the outdoor air. In September there is not enough of one, no matter how good the instrument is. Up here the cold season is long and the differences are large, so the usable window is generous - the constraint is time of day far more than time of year. And a reading in a mild spell is not a pass, it is a null result, which is the distinction that gets lost when somebody is told their building "looked fine".

Air, void and water on a steel wall

A gap that is passing air shows as a trailing plume, sharpest where the gap is - at a door jamb, along a track, or at the ragged hole somebody cut for a hose reel. An area with no insulation or with insulation that has dropped away reads as a flat cold panel, and on a steel building the panel edges line up with the framing so neatly that the pattern is obvious once seen. Water is the odd one out: cool, blurred, crossing framing lines rather than respecting them, cooled by evaporation. In a shop where machinery comes in loaded with snow, the air carries a lot of moisture, and any surface that falls to the point where that moisture condenses will read cold for a reason that has nothing to do with insulation. We separate those two before anybody spends.

What a Whitecourt shop gets out of a survey

Images with locations, a ranked list, and a note on each entry saying whether it is an envelope item, a door item or a moisture item - three different trades and three different budgets. The work that follows tends to be metal building spray foam insulation on the shell, shop spray foam insulation in a working bay, warehouse spray foam insulation on the bigger footprints, and spray foam insulation oilfield tanks out in the yard. An Infrared Home Inspection Whitecourt runs on the same principles in a house, with the attic plane and the exterior corners taking the place of the doors.

Both ends of the job are ours

We take care of the survey and the spraying. The reading and the remedy come from the same crew.

Thermal Imaging Inspection Whitecourt: Common Questions

What does a thermal imaging inspection show in a bay with doors cycling all day? With the building closed up and settled, it shows the envelope - the wall-to-roof junction, the door surrounds and the slab edge. In Whitecourt that slab edge and apron are on the sheet more often than not.

When can you come, then? First thing before the doors start moving, or after hours once it has been shut for a while. Either works; the middle of a shift does not.

Can you scan while it is minus thirty? Yes, and hard cold is exactly what the method wants. It gives a wide contrast across the envelope and the clearest picture of where the heat is going.

The work behind the finding is spray foam insulation. Province-wide detail is on Spray Foam Insulation Alberta and our coverage on service areas.

What we spray in Whitecourt

Spray Foam Applications We Cover in Whitecourt

Spray Foam Insulation Companies Whitecourt: Where We Work

We cover Whitecourt and the surrounding area. For the full service map and the rest of Alberta, start at our service areas.

Ready for a real, honest quote?

Free Spray Foam Quote