A Thermal Imaging Inspection Edson scan often gets ordered by whoever signs the gas bill for a service yard on the highway, after a winter in which the shop cost more to heat than the building behind it earns in a month. The question put to us is never really "where is the heat going". It is "what do I fix first, and what can wait until next year". A camera answers that one, because it ranks the losses instead of listing them.
This is a resource town, so the buildings reflect it. Steel-clad shops with tall bays and overhead doors, mezzanine offices tucked into a corner of the same volume, a truck wash, a parts room that has to stay above freezing. In town the housing is older than people assume — about 66% of homes in Edson were built before 1991 — and a lot of it is 1970s stock put up quickly during a boom, alongside modular homes with a skirted crawl underneath.
A shop that cools down every night
Intermittent heating is the complication here. If a building is turned down when the last truck leaves and hammered back up at six in the morning, its surfaces are nowhere near steady, and a camera pointed at an unsteady building reports the warm-up rather than the construction. We want the heat to have been holding at one setting for several hours, which usually means scanning in the evening after a working day or early on a morning when the thermostat has not been touched. Steady state is not a nicety, it is the condition under which the picture means anything.
What the infrared camera sees at an overhead door
On a shop the doors dominate. Around a door opening we look for the perimeter seal, the header above it, the pocket the door retracts into, and the junction where the steel wall meets the slab. Those read as bright cold frames on the inside face, and they are usually a larger number than the whole roof above them. Infrared is also the only practical way to check a tall wall, because nobody is putting a ladder up to feel for draughts at twenty feet.
What an image is evidence of, and nothing more
A thermogram is proof that one surface is a different temperature than another. That is the entire claim. There is no insulation value in it — a camera cannot report R-6 or R-3.6 or anything else, because it reads the surface and the insulation is behind the surface. It cannot see into the wall assembly, so when we say a bay looks empty we mean the bay behaves as though it is empty, and we confirm that by opening or probing it. Treating the image as a diagnosis rather than a lead is how people end up paying for the wrong repair.
Three patterns on the screen, three different jobs
Air movement shows as smears and tails that spread out from an opening and shift when a bay door is cracked or an exhaust fan runs. Missing insulation shows as rectangles and bands with hard geometric edges, matched to the framing or the panel layout behind them, and it holds perfectly still. Moisture shows as a soft cool region that crosses framing lines, has no straight edge anywhere on it, and is cold because it is evaporating rather than because air is moving past it. In a shop the third one matters more than people expect, because condensation on the inside of a steel skin is a maintenance problem long before it is an energy one.
Thermal imaging in older Edson housing
An Infrared Home Inspection Edson visit to a 1970s house in town goes straight to the places that era got wrong: the top plate of interior walls, the attic hatch, the joist space above the basement wall, and the floor over any skirted or vented crawl. On a modular we also look along the marriage line. The deliverable is the same in both cases: marked images beside plain photographs, grouped by area, ordered worst first, and a foam specification written off that order — closed cell at about R-6 per inch where an air barrier and vapour retarder have to come with the insulation, open cell at about R-3.6 per inch where they do not.
Thermal Imaging Inspection Edson: Common Questions
The shop runs shifts. When can you scan it. When the temperature has been left alone for a while. A building halfway through its morning warm-up gives a picture of the warm-up, not of the walls.
Can you check the ceiling in a tall bay without lifting equipment. Yes. Height is one of the places a camera earns its keep, because reach and touch are not options.
Is it worth doing the office trailer as well. Usually. Site offices and parts rooms in Edson are heated hard, built light, and almost never looked at.
Likely next steps: shop spray foam insulation, metal building spray foam insulation and warehouse spray foam insulation. See also spray foam insulation, Spray Foam Insulation Alberta and our service areas.