About 39% of the homes in this city were built before 1991, and a recognisable share of them are split-levels and four-levels from that era. That shape is the reason a Thermal Imaging Inspection Leduc so often comes back with findings at three different heights instead of one. Every time the floor steps up or down, the framing creates another band of joist ends sitting in the exterior wall, and each of those bands is a separate opportunity for the envelope to stop being continuous.
Then there is the working side of town. The Leduc Business Park and the Nisku Business Park next door are full of service bays, warehouses and yard buildings, and those get scanned on the same cold mornings for entirely different findings.
Leduc split-levels leak at three different floor lines
On a two-storey the band joist is one line and everybody knows to look at it. On a split, the offsets put joist ends above the basement, above the lower living level and under the bedrooms, and the one on the half-landing is the one that gets missed because nothing is finished behind it. From inside, on a cold day, those lines show as cold stripes right where the floor meets the outside wall, and the sequence of them down the house is unmistakable once you have seen it.
What the thermal imaging tells you, and what it leaves open
It tells you the temperature of a surface. That is the measurement, and it is the only measurement. It will not report an R-value, because resistance belongs to a product at a stated thickness and the camera is given neither of those facts. It will not show the inside of the wall. What it leaves open is depth: where a cavity is plainly empty the image is conclusive, and where there is something in there the camera cannot tell you whether it is adequate.
Pulling the house slightly negative sharpens an infrared scan
Here is a trick that costs nothing and settles most arguments. Switch on the range hood and the bathroom fans and the house goes a little under pressure, which means outdoor air is being drawn in through every unfinished joint. Walk the same walls again and the air-movement findings bloom — they get colder, longer and more defined. The cold spots caused by missing material do not change at all, because nothing is moving through them. That one comparison separates a sealing job from a filling job without opening a single wall.
The shapes themselves
Infiltrating air arrives as a cold tongue running away from its entry point, edges feathered, growing under pressure. Absent insulation is a flat cold panel with ruled edges following the framing, static under any condition. Damp is cooler than the dry material beside it because a wet surface gives up heat as it dries, and its outline is soft and arbitrary. The rim joist findings on a split-level are usually the first kind, which is why rim joist spray foam insulation is the most common piece of work to come out of a scan in this city, with basement spray foam insulation or shop spray foam insulation behind it. Closed cell at about R-6 per inch is its own air barrier and vapour retarder, which is why it suits a joist end.
It only works properly in the cold
With little difference between indoor and outdoor air there is almost no heat flow, and a wall with a gap in it reads the same as a wall without one. These get scheduled for cold weather with the building heated normally beforehand.
Thermal Imaging Inspection Leduc: Common Questions
Our split-level has cold floors on the lower level. Is that what you find? Routinely. A complaint like that usually resolves at the joist line rather than under the floor itself, and an Infrared Home Inspection Leduc will show you which of the offsets is responsible.
Can you scan a bay in the business park? Yes, as long as the heat has been on through the night and the doors stay shut while we work.
Do we need to be out of the house? No. We need interior doors open, the normal heat on, and a couple of hours.