Two very different buildings get a Thermal Imaging Inspection Olds in the same week. One is a brick-fronted block on the main street with a shop at grade and a suite or an office above it. The other is a bungalow on a grid street, likely built in the sixties or seventies, with a cold back bedroom. They want the same instrument and they do not want the same reading of it, because masonry and wood frame behave to entirely different timetables. An Infrared Home Inspection Olds on the bungalow is a straightforward hour; the block on the street takes patience.

Thermal imaging on a masonry block takes a longer look

A solid brick or block wall stores an enormous amount of warmth and gives it up slowly. Point a camera at the inside of one in the morning and you are partly seeing yesterday's weather. That thermal inertia is why we scan masonry after a long steady cold stretch rather than on the first cold day, and why we are careful about any wall that had sun on it the previous afternoon. Once the conditions are right, the findings in these old commercial buildings are consistent: an uninsulated back wall against a lane, a stair shaft rising through the building like a chimney, the band where the upper floor framing is pocketed into the masonry, and a storefront header above the glazing that was never detailed to hold heat.

Olds has a century of main street and fifty years of bungalow

About 51% of homes here were built before 1991, which makes the residential half of our work a fairly even split between older frame houses and later subdivisions. In the frame houses the camera keeps finding the top plate, the attic hatch and the floor of any room that sits over an unheated space such as a porch or a garage. In the student and staff rentals near the college, interior boundaries matter as much as the outside walls - a suite conversion that put heated rooms up against an unheated stairwell shows the boundary as clearly as if it were an exterior wall, because to the building it very nearly is one.

Why an infrared reading has hard limits

It measures surface temperature. Not what the wall contains, not how thick it is, and not an R-value - that figure describes insulating material, and the instrument cannot see or identify the material in an assembly. It also does not look through anything; the brick is as opaque to the sensor as it is to your eye. What we work from is the pattern heat leaves on the room-side surfaces on its way out. That is a reliable pattern when the conditions are good, and meaningless when they are not, which is why a scan done on a mild day should be treated as no scan at all.

Air, absence and water

Air shows as a wash. It comes off an opening, spreads out, thins as it goes, and shifts if we change the pressure in the building by shutting it up or running an extractor.

Absence shows as a stripe or a rectangle. It has hard edges, lines up with framing or with the floor structure pocketed into a wall, and nothing we do with doors or fans alters it in the least.

Water shows itself by being late. Evaporation takes heat with it, so damp material reads cooler than what surrounds it and climbs back to temperature long after the dry surfaces have. On the lane-side wall of an old block, a cool area that refuses to warm up is more often water than it is a missing cavity - and the two call for very different work.

What the marked set contains

Images, numbered and located, each with a short explanation of what it indicates and what it does not. Then a scope that follows the images. Where an assembly has to stop air and vapour as well as slow heat - the inside face of masonry, a floor header, anything below grade - closed cell at about R-6 per inch is its own air barrier and vapour retarder and is usually the right call. Where there is a deep framed cavity and a reason to want the room quieter, open cell at about R-3.6 per inch gives more depth for the money and absorbs sound well. We would rather hand over a short honest list than a long speculative one.

Thermal Imaging Inspection Olds: Common Questions

My building is solid brick. Is a scan any use. It is, with the right timing. Masonry responds slowly, so we come after a sustained cold run rather than on the first chilly morning.

Can you tell me what is in the wall of a house without opening it. We can tell you which parts of that wall are behaving as though nothing is in them. For a material answer somebody has to make a hole, and on an older Olds house the scan tells you where to make it.

Do you scan the suite and the shop separately. One visit, both, and the floor between them is frequently the headline finding.

Related: commercial spray foam insulation, wall spray foam insulation, attic spray foam insulation and spray foam insulation. Province-wide: Spray Foam Insulation Alberta. We will prepare a Free Spray Foam Quote from the marked set; the district we cover is on service areas.

What we spray in Olds

Spray Foam Applications We Cover in Olds

Spray Foam Insulation Companies Olds: Where We Work

We cover Olds and the surrounding area. For the full service map and the rest of Alberta, start at our service areas.

Ready for a real, honest quote?

Free Spray Foam Quote