An applicator in coveralls and a respirator spraying closed-cell foam between the steel ribs of a fabricated shop panel

Thermal Imaging Inspection Taber

71%OF TABER HOMES PRE-1991
36APPLICATIONS COVERED IN TABER
R-6PER INCH, CLOSED-CELL
Our own installers Calgary · Edmonton · Red Deer Open 24/7 No price without a site visit
Free quote

Thermal Imaging Inspection Taber: Tell Us The Building

Foam is priced on depth, area, access and prep, so the number comes after someone has seen the space. Send the details and we will come back with a real one.

Get Your Free Spray Foam Quote

Get your spray foam quote

Prefer to talk? Call (403) 703-9512

An applicator in coveralls and a respirator spraying closed-cell foam between the steel ribs of a fabricated shop panel
Supplied by Dustin 2026-08-28

Not every building around here is trying to stay warm. A good share of them are trying to stay cold - vegetable stores, coolers, packing floors - and that turns the usual conversation inside out. A Thermal Imaging Inspection Taber on a storage building is looking for heat coming in rather than leaking away, and the method handles that quite happily, because what the instrument cares about is the difference across the assembly and not which way it points. An Infrared Home Inspection Taber on a house is the ordinary winter version of the same work.

Thermal imaging in a building that is deliberately kept cold

In a produce store the refrigeration plant is the clue to everything. If the machine is running longer than it should, something is admitting warmth, and on a hot afternoon the camera can see where. Typical findings are the perimeter of an insulated door, the junction where a panel wall lands on the slab, penetrations for conduit and drains, and any spot where a forklift has damaged the inner face and nobody has sealed it since. Heat entering a cool building marks the inside surfaces just as plainly as heat leaving a warm one, and a survey done at the peak of a hot day is the mirror image of a survey done at the bottom of a cold night.

Houses need winter, because the rule is really about difference

The requirement people summarise as "it has to be cold out" is actually a requirement for separation between the two sides of a wall. For a heated house in this district that means scanning in the depth of winter, early, before the southern sun loads the walls and leaves warm fields that mask everything underneath. For a chilled building it means scanning when the outdoor air is at its most punishing. Either way, if both sides of the assembly are at a similar temperature there is no image worth taking, and we will say so rather than take one.

Taber's older houses and the sheds around them

About 71% of the homes in town were built before 1991, so most residential scans here are on older frame houses, many of them with later additions and enclosed porches. Recurring findings are the top of the foundation wall, the ceiling perimeter, and the floor of a room built out over a porch or a carport. Beyond the houses, this is irrigation and processing country: equipment sheds, shops, grading and packing buildings, and storage that is conditioned part of the year. Those are read on their own terms, because the thing we are hunting - and the direction it is travelling - is not the same.

A wedge of moving air, a sheet of nothing, and water

Moving air cuts a wedge. It comes in or goes out at a definite point, spreads as it travels and softens at the edges, and it reacts when the pressure in the building changes, whether that is a fan, a door or a refrigeration unit cycling.

A sheet of nothing is still and flat. It covers an area with hard boundaries, generally on the module of the framing or the panel joints, and it does not flinch when anything is switched on or off. That is an assembly with nothing effective in it.

Water announces itself by lagging. Evaporation carries heat away, so a damp area reads cooler than its neighbours and then takes far longer to come back into line when conditions change. In a building that is washed down regularly, distinguishing damp from a true void is most of the skill, and the two call for entirely different work.

What the survey file contains

Every image numbered, located and explained in plain words, followed by a scope assembled out of those images. Panel walls, slab edges, foundation bands and the inside of steel are generally closed cell work at about R-6 per inch, since that product is its own air barrier and vapour retarder as well as insulation - which is what you want wherever the direction of vapour movement can reverse with the season. Where the cavity is deep in a framed wall or a quieter room is part of the goal, open cell at about R-3.6 per inch fills thicker and absorbs sound well. If a line in the scope has no photograph behind it, it should not be in the scope.

Thermal Imaging Inspection Taber: Common Questions

Our cooler runs more than it used to. Can a camera tell us why. Often, yes. We look for the warmth getting in, and door perimeters and wall-to-slab junctions are the first suspects.

Is summer useless for scanning. Not for conditioned buildings. For a heated house in Taber it is, and we will book that one for the winter instead.

Can you scan a shed that has never been insulated. We can, and the useful output is which part of the volume is worth bringing inside the envelope at all, rather than a list of defects.

Related: cold storage spray foam insulation, machine shed spray foam insulation, agricultural spray foam insulation and spray foam insulation. Province-wide: Spray Foam Insulation Alberta. We prepare a Free Spray Foam Quote from the survey file; coverage is on service areas.

What we spray in Taber

Spray Foam Applications We Cover in Taber

Spray Foam Insulation Companies Taber: Where We Work

We cover Taber and the surrounding area. For the full service map and the rest of Alberta, start at our service areas.

Ready for a real, honest quote?

Free Spray Foam Quote