The building a Thermal Imaging Inspection Three Hills has to make sense of is often an upright prairie farmhouse that has stood through a century of winters and been improved four or five times. Somebody has put insulation in the attic. Somebody else has replaced the windows. The upstairs is still cold and the furnace still runs most of the night, and nobody can account for it from the outside. About 66% of homes in Three Hills were built before 1991, and the oldest end of that stock has a structural quirk that explains a lot of these cases.
A balloon-framed wall is a chimney with siding on it
In early prairie construction the wall studs often run unbroken from the foundation sill all the way up past the second floor, with no barrier where the floors meet the wall. That leaves a continuous vertical shaft inside the wall from the basement to the attic. Warm air enters it at the bottom, rises inside the wall the full height of the house, and empties into the roof space, and the whole time it is carrying heat out of rooms it passed on the way. No amount of attic depth touches it, because the air is going up inside the wall, not through the ceiling. On a scan it reads as cold stripes running floor to ceiling on an outside wall, and a matching warm band where it discharges at the attic floor.
Infrared on its own, and infrared with a fan running
A camera by itself shows the result of air movement. Put the house under negative pressure with a fan and the same camera shows the cause, because every opening in the shell starts pulling cold outdoor air inward and the pattern sharpens dramatically. That is how we separate a wall that is merely poorly insulated from a wall that is being flushed with air, and on a balloon-framed house it is the difference between an accurate scope and a guess. We scan once at normal pressure and again with the house depressurised, and we compare the two.
What a thermal image is not
It is not a measurement of insulation. The camera reads the temperature of the surface in front of it and produces nothing else, so no thermogram can report an R-value — that figure describes the material inside the wall and the camera is looking at the paint. It does not see through anything, either. The reason it is still the right first step is that it narrows a whole-house question down to a handful of specific locations, and from there the verification is quick.
Why the cold matters, and why wind helps indoors
Without a strong difference between inside and outside there is no contrast and no information. A still, mild day is a wasted trip. Hard cold is what we want, and on the open ground around town a brisk wind is an asset once we are working inside, because it drives outdoor air through every gap in the shell and makes those gaps obvious on the inside face. Outdoors the same wind is a nuisance, stripping heat off the cladding until nothing stands out, so exterior passes are a minor part of the work here.
Telling the three faults apart
Air shows as feathered streaks that spread from an opening and shift when the pressure changes. An insulation void shows as a hard-edged cold block fixed to the framing and completely static. Moisture shows as a soft cool area with a ragged margin that crosses studs without noticing them, cold because it is evaporating, and unaffected by the fan. Each one has a different remedy, and the reason to look before specifying is to avoid paying for the wrong one.
Thermal imaging inspection in Three Hills: the house and the shop
An Infrared Home Inspection Three Hills appointment generally takes in the farm buildings as well. A heated shop, the insulated end of a pole barn, a calving area — each has its own pattern, usually at the eave, at the base of the wall and wherever a steel fastener or purlin runs straight through the assembly. You get one combined list: marked images paired with plain photographs, grouped by building, ordered by the size of the loss. The foam specification comes out of that list, with closed cell at about R-6 per inch where an air barrier and vapour retarder are needed in the same pass, and open cell at about R-3.6 per inch where filling and sound are the job.
Thermal Imaging Inspection Three Hills: Common Questions
We insulated the attic years ago and it is still cold upstairs. How. If the walls are open from basement to attic, the heat is leaving inside the walls. Attic depth cannot stop that, which is why the work made less difference than expected.
Why run a fan during the inspection. Because depressurising the building turns every hole into a visible cold streak. It is the step that tells us whether we are looking at air or at a gap.
Can you look at the shop on the same visit. Yes, and on most places around Three Hills the heated shop is worth scanning before anything else on the yard.
Where this leads: pole barn spray foam insulation, barn spray foam insulation and shop spray foam insulation. Also spray foam insulation, Spray Foam Insulation Alberta and our service areas.