The usual reason somebody books a Thermal Imaging Inspection Wainwright is that they are holding two opinions that cannot both be right. One trade has said the walls are the problem. Another has said it is the ceiling. Nothing in either conversation was based on looking, because nobody can look through a wall, and the cheque is large enough that guessing wrong hurts. A survey is how that gets decided before the money moves rather than afterwards, and on a farmyard with a house, a quonset and a shop there is usually more than one building competing for the same budget.
What a thermal imaging survey adds to a quote
It adds location. A quote without a survey behind it is a price for a surface somebody picked; a quote with one behind it is a price for the places the building is demonstrably losing heat, in the order they are losing it. What it does not add is a rating. There is no R-value anywhere in a thermal image, because the camera measures how warm a surface is and nothing about the resistance of the material behind it, and it cannot see through anything. Those two sentences are the fair description of the tool.
A quonset reads differently from a stud wall
The arch is its own case. There are no studs, the structure is a series of ribs, and the inside face curves continuously from the slab to the crown, so there is no flat plane and no regular framing pattern to use as a reference. What shows up instead is banding that follows the ribs, which is normal, and then the real findings: the end walls, which are usually conventional framing bolted onto an arch and almost never sealed where the two meet, and the bottom few feet of the arch where it lands on the footing. A grain or equipment building that frosts up inside is nearly always telling us about those joints.
Wainwright houses and the ceiling plane nobody has opened
About 63% of homes in Wainwright were built before 1991, which here means a lot of post-war and later bungalows with a shallow attic, a bathroom fan vented into it at some point, and a hatch in a closet with nothing over it. The image on those is consistent: a bright patch at the hatch, a warm line along every interior top plate where warm air is pushing up into the attic, and the ring around every ceiling fixture. Owners expect the walls to be the finding and the ceiling plane almost always outranks them.
An Infrared Home Inspection Wainwright and the three readings
An Infrared Home Inspection Wainwright comes down to telling three things apart, and they look genuinely different once you know what you are looking at. Air travelling through a gap spreads out from its entry and feathers away downstream, so it reads as a smear with a direction. Insulation that is absent reads as a hard-edged cold block, the edges set by whatever framing bounded the space. Moisture reads as a soft, borderless cool area, because evaporating water removes heat from the surface it is leaving, and that one we verify with a meter before it goes on any list.
Cold, dark, and before the wind gets up
The scan needs a real difference between inside and outside, which means the cold months and not a mild week, because without a difference the camera has nothing to render. On the open prairie the other thing we watch is wind: a strong wind drives every leak hard, which makes them easy to see but harder to weigh against each other, so a clear cold morning before it picks up gives the most balanced picture. Sun-loaded walls get left until later or scanned the following morning.
What is in the hand-over
Photographs grouped by building, each finding written out in plain words and ranked by what it is costing, so the two opinions that started the whole thing can be settled by looking at the same page. Then a scope that follows the findings: closed cell at about R-6 per inch where the surface has to be its own air barrier and vapour retarder, which is the usual answer on an arch, a rim joist or a steel wall, and open cell at about R-3.6 per inch where the cavity is deep and dry and sound is part of the brief.
Thermal Imaging Inspection Wainwright: Common Questions
Two contractors told me two different things. Will a scan settle it? That is the main thing it is for. A photographed, located list of losses is harder to argue with than two recollections of standing in a cold room.
Our quonset frosts on the inside. Is the roof leaking? Almost certainly not. Moist air inside meeting cold steel overhead produces frost, and on a Wainwright quonset the air is usually getting in at the end walls or at the base of the arch.
Do you need the house empty and the shop shut down? Not empty, but we do need both heated as they normally are, and we need the shop doors closed for a good while beforehand so the cold at the opening is not all we can see.
What normally follows: quonset spray foam insulation, attic spray foam insulation or machine shed spray foam insulation. See also spray foam insulation, spray foam insulation across Alberta and our service areas.