An applicator in coveralls and a respirator spraying closed-cell foam between the steel ribs of a fabricated shop panel

Thermal Imaging Inspection Claresholm

72%OF CLARESHOLM HOMES PRE-1991
36APPLICATIONS COVERED IN CLARESHOLM
R-6PER INCH, CLOSED-CELL
Our own installers Calgary · Edmonton · Red Deer Open 24/7 No price without a site visit
Free quote

Thermal Imaging Inspection Claresholm: Tell Us The Building

Foam is priced on depth, area, access and prep, so the number comes after someone has seen the space. Send the details and we will come back with a real one.

Get Your Free Spray Foam Quote

Get your spray foam quote

Prefer to talk? Call (403) 703-9512

An applicator in coveralls and a respirator spraying closed-cell foam between the steel ribs of a fabricated shop panel
Supplied by Dustin 2026-08-28

Ask anybody who has lived under the Porcupine Hills what the house does in a blow and you will hear about the west rooms. A Thermal Imaging Inspection Claresholm turns that complaint into a picture, because wind is not a vague nuisance - it is a pressure, it pushes outdoor air through any route it can find, and the chilled trail that air leaves on the inside finish is something a sensor can see plainly. An Infrared Home Inspection Claresholm run during a steady westerly is one of the more revealing hours you can spend on an older building here.

The wind does half the work of an infrared survey

Pressurise one face of a building and air enters wherever the detailing is weak. That is what a strong afternoon off the slope does for free, and it is why we deliberately schedule scans for breezy cold days rather than still ones. On the upwind side we watch cold creeping inward at window surrounds, at the junction of the wall and the ceiling, behind baseboards and around the box of a bathroom fan. On the downwind side the same house pushes warm indoor air outward instead, so the finish stays warm and those identical gaps go quiet. Half a survey here consists of comparing the two sides of one building and understanding why they disagree.

Thermal imaging measures a surface and stops there

Worth being blunt about. The instrument returns the temperature of the face it is aimed at - the paint, the panel, the floor, the sill - and nothing deeper. It will not produce an R-value, because R-value is a property of insulating material and the camera has no way of knowing what material is in there or how much. It also does not look through the wall; that is a myth we spend part of every visit dismantling. What we actually interpret is a pattern of warm and cool left on the room side by heat and air taking the easiest way out.

Claresholm buildings and what the lens keeps finding in them

Roughly 72% of homes in town were built before 1991, which is a high share even by small-town Alberta standards, and much of it is single-storey with a shallow attic and wide eaves. Soffit openings that face into the prevailing wind let cold scour the outer edge of the ceiling, and that shows as a chilled border running the perimeter of upstairs rooms rather than a single spot. Out on the ranch yards it is the shop and the calving barn: steel skins, big doors, and heated corners inside unheated volumes. Around the old training airfield there are low utility buildings now used for storage and light work, and those were never built to hold heat at all - with those we are mostly mapping which portion is worth bringing inside the envelope.

A windward leak, an unfilled bay and a wet sill look nothing alike

A wind-driven leak has direction and it moves. It reaches inward from its entry point as a cold spread that loses strength with distance, and it strengthens or weakens with the gusts. Stand and watch one for a minute and it breathes.

An unfilled bay has no direction and no motion. It is a straight-sided panel, usually the width of the space between two studs, and identical whether the wind is up or down. Where you find three or four in a row at the same height, you are usually looking at the band above a basement wall.

A wet sill reads cool because drying takes heat with it. The giveaway is sluggishness: dry surfaces in the room respond when the heat comes on and a damp one does not, staying behind for a long while. Timing, not colour, separates water from air.

What you get at the end of the appointment

Labelled photographs, each tied to a room or an elevation, written notes explaining what the pattern indicates, and a scope limited to what the photographs justify. Where air and vapour both need stopping - a rim joist, a crawl space wall, the back of a knee wall - closed cell at about R-6 per inch does all three jobs at once, being an air barrier and vapour retarder as well as insulation. Where the cavity is deep and the priority is depth and quiet, open cell at about R-3.6 per inch is the better choice. The survey exists so that decision is made on evidence.

Thermal Imaging Inspection Claresholm: Common Questions

Should you come on a calm day so the readings are fair. The opposite. Wind is the pressure that reveals air leakage, and a dead-still day hides exactly what we were hired to find.

The west bedrooms are cold and the east ones are fine. Is that insulation. Sometimes, but in Claresholm it is more often air. The survey distinguishes them, and they get fixed differently.

Can you scan the shop and the house on the same call. Yes. One cold morning generally covers a yard, and the two buildings fail in quite different places.

Related: wall spray foam insulation, basement spray foam insulation, agricultural spray foam insulation and spray foam insulation. Province-wide detail: Spray Foam Insulation Alberta. Ask for a Free Spray Foam Quote when the photographs are in front of you, and see service areas for the district we cover.

What we spray in Claresholm

Spray Foam Applications We Cover in Claresholm

Spray Foam Insulation Companies Claresholm: Where We Work

We cover Claresholm and the surrounding area. For the full service map and the rest of Alberta, start at our service areas.

Ready for a real, honest quote?

Free Spray Foam Quote