Thermal Imaging Inspection Lethbridge has one variable to manage that most of the province can ignore, and it is the wind. A building in a city this exposed does not sit in still air waiting to be measured; it is being pressurised on one face and depressurised on the other for most of the winter, and every gap in the envelope is being actively driven rather than merely leaking. That changes what shows up on an image and it changes how the image has to be read. About 59% of homes in Lethbridge were built before 1991, and in a wind like this the age of a house matters far less than whether anybody ever sealed it.
What a thermal imaging inspection can and cannot tell you
It can tell you, to within a hand's width, where a surface is colder than the surface around it. It cannot tell you the thermal resistance of the assembly behind that surface — an R-value is not something a camera is capable of observing — and it cannot see through a wall to count what is in there. Everything beyond the surface is inference. Good inference, when the conditions and the interpretation are sound, and nothing at all when they are not.
Wind washing, and why a wall can be full and still read cold
This is the finding that surprises people here. Air entering at a soffit or through a lap in the cladding can travel sideways through a loose insulation layer, stripping heat as it goes, without any of the material being absent. Open the wall afterwards and it looks fine, because it is fine — it just has outdoor air moving through it. On an image that shows as a broad, streaky cold area that runs with the wind rather than with the framing, and it is the reason we ask which way the house faces before we start.
An Infrared Home Inspection Lethbridge is timed, not just booked
An Infrared Home Inspection Lethbridge needs two conditions, and the second one is specific to this city. There must be a real temperature difference across the envelope, which means cold weather, because a camera renders differences and a mild day gives it nothing to render. And we want to know what the wind is doing, because a strong wind exaggerates every air leak on the windward side and suppresses the ones on the lee. A scan on a still cold morning and a scan in a blow are two different sets of information, and on a problem building both are worth having.
Three signatures, read in a wind
Driven air announces itself: a plume out of a joint, drawn out long and thin in the direction of travel, often reaching much further across a wall than people expect. Missing insulation stays put: a cold field bounded by framing, the same shape whatever the weather is doing. Moisture is the quiet one, a soft cool area with no edges, caused by evaporation taking heat off the surface, and because it is so easily confused with a wind-washed patch we put a meter on it before it goes in a report. Those three readings are the whole basis of the work.
What ends up in your hands
Images grouped by elevation as well as by room, which matters in a city where one side of a building behaves differently from the other, each finding labelled as driven air, absence or unconfirmed damp, and the lot put in the order it is worth spending on. Then the material choice follows the finding rather than the fashion: closed cell at about R-6 per inch where the surface has to stop the air and the vapour itself, and open cell at about R-3.6 per inch where the cavity is deep, dry and sound is part of the brief.
Thermal Imaging Inspection Lethbridge: Common Questions
Should you scan on a windy day or a calm one? If we can only have one, a cold calm morning gives the cleaner baseline. A windy day is better for hunting leaks, which is why a problem house in Lethbridge sometimes gets both.
The wall was opened up and the insulation was all there. So why is that room cold? Very likely wind washing. Outdoor air travelling through a loose layer removes heat without removing any material, and the image shows it as a streak running across the framing rather than along it.
Can you scan a commercial unit out in the industrial parks? Yes. Those buildings are mostly steel, and the method is the same with one extra step, which is separating the normal girt pattern from an actual defect.
Afterwards the work is usually wall spray foam insulation, attic spray foam insulation or closed cell spray foam insulation. See also spray foam insulation, spray foam insulation across Alberta and our service areas.